C3-4013-B

Technical specifications

CodeWattCRIFluxSizeBeamCCT
C3-4013-B14 W97 CRI1000–1200 lmØ60 × 300 mm15° 24° 36° 60°3000, 4000 K
LED source
Citizen
Colour temperature
3000, 4000 K
Beam angles
15°, 24°, 36°, 60°
Control
Triac, Casambi, DALI-2, 0–10 V
Mounting
Surface
IP rating
IP20
Certifications
CE, RoHS, EMC, LVD

Photometry

C3-4013-B. Polar curve (C0–C180 solid, C90–C270 dashed, cd/klm) and key figures from the same data as the IES and LDT files: calculated from catalogue data, not measured.

0°30°60°30°60° 44988995 cd/klm C0–C180 C90–C270
18°
Power
14 W
Luminous flux
729 lm
Efficacy
52 lm/W
Peak intensity
6,556 cd
Field angle (10%)
32.8°
At 3 m
728 lx, Ø0.95 m
0°30°60°30°60° 11452289 cd/klm C0–C180 C90–C270
36°
Power
14 W
Luminous flux
1,428 lm
Efficacy
102 lm/W
Peak intensity
3,268 cd
Field angle (10%)
65.6°
At 3 m
363 lx, Ø1.95 m
0°30°60°30°60° 646512930 cd/klm C0–C180 C90–C270
15°
Power
14 W
Luminous flux
1,000 lm
Efficacy
71 lm/W
Peak intensity
12,930 cd
Field angle (10%)
27.3°
At 3 m
1,437 lx, Ø0.79 m
0°30°60°30°60° 25425083 cd/klm C0–C180 C90–C270
24°
Power
14 W
Luminous flux
1,000 lm
Efficacy
71 lm/W
Peak intensity
5,083 cd
Field angle (10%)
43.7°
At 3 m
565 lx, Ø1.28 m