D3-4018

Technical specifications

CodeWattCRIVoltageFluxSizeBeamCCTCut-out
D3-401828 W97 CRI220–240 V AC3000–3200 lmØ160 x H109 mm12° 30° 36° 45° 60°3000, 4000 KØ145 mm
D3-401835 W97 CRI220–240 V AC3700–3900 lmØ160 x H109 mm12° 30° 36° 45° 60°3000, 4000 KØ145 mm
D3-401843 W97 CRI220–240 V AC4600–4800 lmØ160 x H109 mm12° 30° 36° 45° 60°3000, 4000 KØ145 mm
LED source
Citizen
Colour temperature
3000, 4000 K
Beam angles
12°, 30°, 36°, 45°, 60°
Control
On/Off, Triac, Casambi, DALI, 0–10 V
Mounting
Recessed
IP rating
IP20
Certifications
CE, RoHS, EMC, LVD

Photometry

D3-4018. Polar curve (C0–C180 solid, C90–C270 dashed, cd/klm) and key figures from the same data as the IES and LDT files: calculated from catalogue data, not measured.

0°30°60°30°60° 646512930 cd/klm C0–C180 C90–C270
15°
Power
43 W
Luminous flux
821 lm
Efficacy
19 lm/W
Peak intensity
10,616 cd
Field angle (10%)
27.3°
At 3 m
1,180 lx, Ø0.79 m
0°30°60°30°60° 7431485 cd/klm C0–C180 C90–C270
45°
Power
43 W
Luminous flux
5,160 lm
Efficacy
120 lm/W
Peak intensity
7,660 cd
Field angle (10%)
82°
At 3 m
851 lx, Ø2.49 m
0°30°60°30°60° 430860 cd/klm C0–C180 C90–C270
60°
Power
43 W
Luminous flux
5,077 lm
Efficacy
118 lm/W
Peak intensity
4,368 cd
Field angle (10%)
109.4°
At 3 m
485 lx, Ø3.46 m
0°30°60°30°60° 1008720173 cd/klm C0–C180 C90–C270
12°
Power
43 W
Luminous flux
4,600 lm
Efficacy
107 lm/W
Peak intensity
92,794 cd
Field angle (10%)
21.9°
At 3 m
10,310 lx, Ø0.63 m