S3-0074

Technical specifications

CodeWattCRIFluxSizeBeamCCT
S3-007410 W97 CRI1100–1200 lm163 × 44 × 30 mm35° 50° 65° 80° 90°3000, 4000 K
LED source
Citizen
Colour temperature
3000, 4000 K
Beam angles
35°, 50°, 65°, 80°, 90°
Control
Triac, Casambi, DALI, 0–10 V
Mounting
Magnetic track
IP rating
IP20
Certifications
CE, RoHS, EMC, LVD

Photometry

S3-0074. Polar curve (C0–C180 solid, C90–C270 dashed, cd/klm) and key figures from the same data as the IES and LDT files: calculated from catalogue data, not measured.

0°30°60°30°60° 372743 cd/klm C0–C180 C90–C270
65°
Power
10 W
Luminous flux
1,529 lm
Efficacy
153 lm/W
Peak intensity
1,136 cd
Field angle (10%)
118.5°
At 3 m
126 lx, Ø3.82 m
0°30°60°30°60° 12102419 cd/klm C0–C180 C90–C270
35°
Power
10 W
Luminous flux
1,100 lm
Efficacy
110 lm/W
Peak intensity
2,660 cd
Field angle (10%)
63.8°
At 3 m
296 lx, Ø1.89 m
0°30°60°30°60° 6071213 cd/klm C0–C180 C90–C270
50°
Power
10 W
Luminous flux
1,100 lm
Efficacy
110 lm/W
Peak intensity
1,334 cd
Field angle (10%)
91.1°
At 3 m
148 lx, Ø2.80 m
0°30°60°30°60° 259518 cd/klm C0–C180 C90–C270
80°
Power
10 W
Luminous flux
1,100 lm
Efficacy
110 lm/W
Peak intensity
570 cd
Field angle (10%)
145.8°
At 3 m
63 lx, Ø5.04 m