Fort DL1889

Technical specifications

CodeWattCRIVoltageFluxSizeBeamCCTCut-outNotes
DL188910 W97 CRImax 19 V3 × 960 lm252 × 92 x H71 mm15° 24° 36° 55°2700, 3000, 4000 KØ3 mm500 mA
DL188513 W97 CRImax 37 V3 × 1180 lm252 × 92 x H71 mm15° 24° 36° 55°2700, 3000, 4000 KØ3 mm350 mA
LED source
Citizen
Colour temperature
2700, 3000, 4000 K
Beam angles
15°, 24°, 36°, 55°
Mounting
Recessed
IP rating
IP20
Certifications
CE

Photometry

DL1885. Polar curve (C0–C180 solid, C90–C270 dashed, cd/klm) and key figures from the same data as the IES and LDT files: calculated from catalogue data, not measured.

0°30°60°30°60° 646512930 cd/klm C0–C180 C90–C270
15°
Power
13 W
Luminous flux
3,540 lm
Efficacy
272 lm/W
Peak intensity
45,771 cd
Field angle (10%)
27.3°
At 3 m
5,086 lx, Ø0.79 m
0°30°60°30°60° 25425083 cd/klm C0–C180 C90–C270
24°
Power
13 W
Luminous flux
3,540 lm
Efficacy
272 lm/W
Peak intensity
17,994 cd
Field angle (10%)
43.7°
At 3 m
1,999 lx, Ø1.28 m
0°30°60°30°60° 11452289 cd/klm C0–C180 C90–C270
36°
Power
13 W
Luminous flux
3,540 lm
Efficacy
272 lm/W
Peak intensity
8,103 cd
Field angle (10%)
65.6°
At 3 m
900 lx, Ø1.95 m
0°30°60°30°60° 5061012 cd/klm C0–C180 C90–C270
55°
Power
13 W
Luminous flux
3,540 lm
Efficacy
272 lm/W
Peak intensity
3,584 cd
Field angle (10%)
100.2°
At 3 m
398 lx, Ø3.12 m